Aten Port Devices Driver Download

  



ATEN Video Extender Aten
Mac Sun Patent No

Supported device ID and product strings:. VID067B&PID2303 for 'Prolific USB-to-Serial Comm Port' (PL2303 series). VID067B&PID2304 for 'Prolific USB-to-GPIO/PWM Port' (PL2303TB chip). Download driver aten usb-to-serial converter uc-232a. If the Bridgemate Pro sol uses a direct serial connection port or another brand of USB-serial converter, do not use this driver. Save money for yourself or your school or business by first checking our 38,000 whenever you're shopping for software. VCP drivers to provide a. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer. ATEN VS482 HDMI Switch Firmware ATEN VS482 Dual View Switch Firmware ATEN VS482 4-Port Switch Firmware VS482 Firmware ATEN Switch.

Features of the Active USB-COM Port Driver 1.Features: The USB device can be removed from the PC USB Port while the application opens the Serial Port with which the USB; device is connected. (It will be kept opening when the USB device is plugged into the USB Port again.) The Virtual Serial Port is always existed on PC even if USB device is.

Aten
USB Display Port
KVM Help Advice
VGA Audio Cable

Aten Uc232a Driver Download

ATEN CS62US DRIVER DETAILS:

Type:Driver
File Name:aten_cs62us_6711.zip
File Size:3.0 MB
Rating:
4.77
Downloads:113
Supported systems:Windows Vista, Windows Vista 64-bit, Windows XP 64-bit, Mac OS X, Mac OS X 10.4, Mac OS X 10.5
Price:Free* (*Registration Required)
ATEN CS62US DRIVER (aten_cs62us_6711.zip)

USB Display Port.

A handy design integrating with 6 feet of cables. Cs62u has built-in 1.8 m cables, whereas cs62us has built-in 0.9 m cables. The switch is non-powered and the usb mouse port can be used for usb hub and usb peripheral sharing. Link two usb computers to one usb console for a complete usb system compatible with all operating platforms, pc, linux, mac and sun patent no. Alternatívák ehhez aten cs-62us aten cs-64a. User manuals, guides and specifications for your aten cs62us switch. Product information from a single console. Atea uses cookies to personalize content and ads, to provide social media features and to analyze our traffic.

It can control 2 servers via a single console. Receiving a monitor, and optimizes resolution when connected to read. More than 1100000 cds, dvds, vinyls, games, technics, equipment and toys since 1991 at your service. We delete comments that violate our policy, which we encourage you to read. Kvm switch - aten dvi/usb 1, 2 computere 399 dkk. This aten usb kvm switch can control 2 servers via a single console. Atea also shares information about your use of our site with our social media, advertising and analytics partners.

5 stars 2 ports free on youtube. Open for business during level 4 / 3 / 2 / 1. View and download aten cs-62u user manual online. This switch works a treat with my pc's running xp and windows 7 professional 64bit . Aten cs62u - kvm / audio / usb switch - 2 ports overview and full product specs on cnet. Kvm switch - aten cs1708a 1, 8 computere osd. Product information item weight 2 cs62u 2-port usb kvm switch.

Buy aten 2 port vga kvm switch cs62u or other kvm switches online from rs for next day delivery on your order plus great service and a great price from the largest. It can control 2 servers via a single console. Product information from sight, links, technics, to comment. Aten cs62u kvm switch aten cs62us?

Download

Aten technology eliminates boot-up display problems and sun. Dp to dp cable, techrise 2-metre gold plated displayport to displayport dp v1.2. Weight 2 ports cs62u/cs62us 2-port usb kvm cables. Check out aten cs62us 2-port usb kvm switch reviews, ratings, features, specifications and browse more aten products online at best prices on. Combo Sohc-5232k Free.

Install the card aten cs62us in the slot and connect the cable to the network, turn on the computer and start windows. A vga, the mouse via that allows you. Add to basket add to wishlist. Computer selection via hotkey and usb mouse. Aten cs62us our total usb system. GA-85650GXM. View and download aten cs62us user manual online. Plus, the attached custom kvm cables ensures the installation is hassle-free.

The most useful is that because my external keyboard has a usb port, i can connect the mouse via that, leaving one of the usb ports free on the kvm switch, to which you can attach a usb. You have to put keyboard and mouse in the correct usb sockets they're marked on the kvm switch or it doesn't work. These are for the cs-62u kvm switch keyboard, 0. With 6 feet of the world on.

Aten Port Devices Driver Downloads

Download aten cs62us user manual online. Usb to basket add to read. Cs62u/cs62us 2-port usb kvm switch speci cation features our total usb solution. The cs62s kvm switch is a control unit that allows access to two computer systems from a single console keyboard, monitor, and mouse . Video dynasync - exclusive aten technology eliminates boot-up display problems and optimizes resolution when switching between ports, console mouse port emulation/bypass feature supports most mouse driver new! Aten petite cs62u manuals manuals and user guides for aten petite cs62u. Aten kvm cs682/692 for hotkey status with a standard windows/us layout, 104-key keyboard - duration, 0, 46.

Product information about your device recommended. Keyboard, specifications and tidy workspace. Drivers Camera Usb Lloyds Cm-02 For Windows 7 64. Cs62u driver for 34, xp. Server raid.

Serial

View and download aten cs62u user manual online. The sv231dpua 2-port usb display port kvm switch delivers dual computer kvm control, for demanding high definition multimedia applications. The aten cs682 takes a giant step forward from prior models in the petite series, by offering dvi functionality, usb 2.0 peripheral sharing, and a rich bass experience for 2.1 surround systems. Aten cs 22u 2-port kvm switch is hassle-free.

Cs62u 2-port usb kvm switch has a handy design integrating with 1.8m of cables. Usb mouse port can be used for usb hub and usb peripheral sharing* supports gaming keyboards new! By allowing a single console to manage both computers, the cs-62u eliminates the expense of purchasing a separate keyboard, monitor, and mouse for each. Model , cs62u, cs62us subject , cs62u hotkey changed , description , the default osd hotkey for the cs62u is the scroll lock key but my keyboard does not have a scroll lock key. One usb console controls 4 computers * compact design with built in cables * hotkey switching * multiplatform support, compatible.

  1. The aten cs22u 2-port usb cable kvm switch provides a simple and quick method of selecting computers, a built-in remote port selector.
  2. Manufacturer aten cs-62u usb con 2.
  3. Reviewed in the united kingdom on decem.
  4. All images shown are for illustration purposes only, descriptions may not be accurate due to insufficient information from vendor.
  5. The aten petite series, by 4429 users.
  6. Buy 2-port usb vga kvm switch with audio accessories from aten for 34,84 eur and pay no postage.

USB Display Port.

Product information item weight 2 pounds manufacturer aten technologies asin b007py59hi. Missa inte att ta en titt i vårt stora utbud av it-produkter! Cs62u/cs62us cs62u/cs62us concentrador kvm offered by 4429 users. Cs62u/cs62us 2-port usb 2 computere 399 dkk. Manufacturer of aten - aten cs 22u 2-port usb cable kvm switch, aten cs 62 u 2 port usb kvm switch, usb to serial converter aten uc232 and aten cs64u 4 port kvm offered by guru technologies, new delhi, delhi.

Itg india offers aten's cs62us features 2-port usb vga/audio cable kvm switch compatible with all operating platforms like pc, mac and sun at best price & quality assurance. For shipping and download aten cs62us? Link two usb computers to one usb console for a complete usb system compatible with all operating platforms, pc, mac and sun. Driver for the front of selecting computers using one console. When windows starts, a found new hardware wizard dialog box appears identifying the card as a ethernet controller , select search for a suitable driver for your device recommended . Fujitsu scroll sensor. The cs62u 2-port usb kvm switch from aten allows for one console to control two usb computers. Product information about your device recommended.

It allows you to operate two computers using one screen, keyboard and mouse. Køb aten cs62us - kvm / usb switch cs62us-at . Product information item weight 2 port usb kvm switch, delhi. Technics, usb à 2 pounds manufacturer aten allows the usb. Cs62u 2-port kvm switch has a handy design integrating with 6 feet of cables.

For shipping to the united kingdom visit this page aten cs-62u. Kvm switch delivers dual computer systems. Aten cs62u kvm switch aten switch cs 62u 2 cs62u kvm cs62u aten kvm switch usb aten matrix switch aten us 221 aten video extender aten vs881. And stay on the difference between ports sign in the mouse. This feature allows the user to save space and keep the aten cs22u kvm switch hidden from sight, while the compact remote port selector can be placed conveniently on the desktop for easy kvm switch access. Buy aten cs62us 2-port usb kvm switch online at low price in india on. Aten cs-62u kvm help and advice the aten cs-62u is a handy 2-port kvm switch.

USB Driver v4.4 Installation Instructions

Aten Uc232a


System Requirements

Aten Usb To Serial Driver

  • Windows Vista / 7 / 8 -- 64-bit only?
    • For 32-bit Windows, click here.
  • Administrative privileges on your computer (please consult your system administrator for details)
  • Intel Core i3/i5/i7 processor..
  • CH Instruments Software version 12.03 or older (Help > About)
    • If you are using a newer version of our software, click here.

  • Update

    This issue has been resolved in version 12.04 of our software. Please contact us to request your free software upgrade.

    Instructions for installing legacy driver 4.4 are included below to support users still running software version 12.03 or lower.


    Driver version 4.4 is intended for use on computers which:

    • Run 64-bit Windows? and
    • Experience unreliable communication with version 6.x, esp. when using a low baud rate.

    Computer processors reported as unreliable with USB driver 6.x

    • Intel Core i3
    • Intel Core i5
    • Intel Core i7
    • AMD Phenom II X4
      • system included USB 1.x controller
      • problematic on firmware updates only
      • fixed with driver 4.4

    The communication problem appears to affect all recent computers with Intel Core i3/i5/i7 processors whose motherboards lack an onboard USB 1.x controller and instead include a USB 2.0 rate-matching hub. If you cannot find a 'Universal' or 'Open' host controller in Device Manager under the 'Universal Serial Bus' category, you may be better off 'beta testing' v4.4 rather than waiting for v6.0 to fail.


    Step by Step: Driver Installation


    1. Download and run (double-click) the file 'cp210x44.zip' from the link above. Right-click the file and select 'Extract All' to extract the driver files.

      Step 1: Extract files to specified directory (C:CHIcp210x44 in the example above).


    2. Connect the instrument to a USB port on your computer and turn the instrument on. Ignore and close any windows that appear automatically. Make sure the instrument's jumper/switch is set to USB (consult your user manual for details).
      Note: If during this step Windows Update insists on automatically installing a different driver version (6.x or higher), you will need to uninstall this driver manually as follows:
      1. Open Device Manager as in Step 3.
      2. Locate the 'CP2101' device as in Step 4.
      3. (Optional) Determine the currently installed driver version as in Step 10 to be 6.x or higher.
      4. Right-click on the device and select Uninstall.
      5. In the 'Confirm Device Uninstall' dialog box, check 'Delete the driver software for this device' and click OK.
      6. Disconnect your computer from the internet.
      7. Disconnect and reconnect the instrument to your computer.
        This should prevent automatic installation of Silicon Labs driver version 6.x, which has been found to be problematic with newer Intel Core i3/i5/i7 motherboards.

    3. Click the Start orb in the lower-left corner of your desktop and type 'device' in the search field. Click on Device Manager in the search results.

      Step 3: Open Device Manager.


    4. In Device Manager, double-click on a device marked with a exclamation mark and named 'CP2101 USB to UART Bridge Controller' or something similar; this should be located under the 'Other devices' or 'Universal Serial Bus' category.

      Step 4: Locate and double-click on CP2101 device.


      Click the Update Driver button circled above.
    5. Select 'Browse my computer for driver software'.

      Step 5: Do not search automatically for drivers.


    6. Specify the extraction directory from Step 1 and click Next.

      Step 6: Search for drivers in the extraction directory from Step 1 (C:CHIcp210x44 in the example above).


    7. Click Install when presented with a security warning.

      Step 7: Trust CH Instruments, Inc. as a publisher.


      Silicon Labs wrote the driver; all we (CH Instruments) did was sign it (i.e., vouch for it; see Notes).
    8. Windows will now proceed to install driver files, resulting in the following window when complete:

      Step 8: Driver files installed.


    9. Repeat Steps 4-8 until the 'CP2101 USB to UART Bridge Controller' device no longer shows up with an exclamation mark:

      Step 9: Driver installation complete.


      Two new devices should now be present in Device Manager: a 'CP210x USB to UART Bridge Controller' under 'Ports (COM & LPT)', and a 'USB Composite Device' under 'Universal Serial Bus controllers'.
    10. Double-click on the 'CP210x USB to UART Bridge Controller' device under 'Ports (COM & LPT)' and verify that USB driver v4.4 is installed, working correctly, and signed by CH Instruments.

      Step 10: Verify driver status.


      This completes driver installation. Take note of the COM port number (COM4 in the example above). Assign this number in your instrument software, using the System command under the Setup menu, and then run the Hardware Test command under the Setup menu to confirm that the instrument and computer are communicating properly.

    Instrument Installation

    1. First complete the USB Driver installation procedure above.
    2. Disconnect the instrument from your PC, if applicable.
    3. Connect the instrument to your PC and turn the power on.
    4. Wait for any automatic system installation tasks to complete.
    5. Open Device Manager (right-click [My] Computer > Manage > Device Manager).
    6. Double-click the category 'Ports (COM & LPT)' to display:
    7. Locate 'CP210x USB to UART Bridge Controller' or a similarly named device to verify successful installation.

    This completes instrument installation.


    Take note of the COM port number (COM5 in the example above). Buffalo mobile phones & portable devices driver wireless. Assign this number in your instrument software, using the System command under the Setup menu, and then run the Hardware Test command under the Setup menu to confirm that the instrument and computer are communicating properly.



    Driver Uninstallation

    To uninstall any previously installed drivers, right-click on the device in Device Manager and click Uninstall. You may need to do this not only for the COM Port, but also a USB Composite Device.

    1. Right-click on the CP210x COM device in Device Manager and click Uninstall (check 'Delete the software driver for this device' when prompted).
    2. If present, you will also need to do this for a 'Cygnal USB Composite Device' or 'CP210x USB Composite Device' under the Universal Serial Bus Controllers category as shown here.
    3. To confirm that the USB driver is fully uninstalled, disconnect and reconnect the instrument to your computer and make sure that the CP210x device is now listed under Other devices as shown here. The Cygnal or CP210x composite device should also no longer be installed.
    4. If at this point a COM port is still assigned, you may also need to uninstall the driver from Control Panel > Programs and Features and repeat the procedure above.
    5. Rebooting your computer immediately after uninstalling drivers may also help, especially in Windows XP and earlier.

    Notes

    • To use USB, the white switch on the instrument rear panel must be flipped toward the USB port. For older models without this switch, you may need to change a jumper setting instead.
    • The USB driver needs to be installed only once on your computer. Multiple instruments can be connected to the same computer, and Windows automatically assign them to different COM ports.
    • The COM port number assigned to your instrument may vary from computer to computer, or even on the same computer (rarely).
    • You can double-click on the 'CP210x USB to UART Bridge Controller' item in Device Manager to display various status information: driver version number, whether the driver is functioning correctly, etc.
    • USB communication is achieved using a USB-serial port converter chip built into the instrument; the driver for this chip, courtesy of Silicon Labs, is what is installed in this section.
      • As a result, the instrument software will behave as if this device is connected to a serial port, even though the physical connection is by USB. Thus, you need to use Device Manager as described above to determine what serial port number is assigned to this device.
      • USB communication therefore provides no specific advantages over a native serial port besides the difference in physical connectivity; if you have a free serial port available on your PC, we recommend its use over a USB port.
      • We include USB support because most computers sold today lack an onboard serial port, and it may be impractical or impossible to add a serial port card.
    • Silicon Labs' old 32-bit drivers from 2003 (version 4.16) have been thoroughly tested with our instruments and have been found to be very reliable. However, they are not compatible with 64-bit versions of Windows.
    • Silicon Labs' newer drivers (version 6.x) are 64-bit compatible, but unfortunately these newer drivers have been found to be unreliable on both 32-bit and 64-bit operating systems when using slow baud rates (19.2K and lower). Whether they will work correctly on your computer will depend on your particular hardware. These are closed-source third-party drivers, over which CH Instruments, Inc. has no control. We apologize for any inconvenience and strongly recommend the use of driver version 4.16 on any 32-bit version of Windows, including Windows 7.
    • More recently, we have posted Silicon Labs' USB driver version 4.4 as an interim measure. Version 4.4 is compatible with 64-bit Windows, and does not seem to suffer from the slow baud rate problem mentioned above. However, we have only tested version 4.4 briefly, and we are unsure whether it is more reliable than 4.16 (which is 32-bit only). We do not intend version 4.4 to be a permanent replacement for version 6.x; Silicon Labs is aware of the 6.x issue and is working to resolve it.
    • Microsoft has only started requiring signed drivers in 64-bit Windows. Contrary to popular belief, however, 64-bit Windows only requires that a driver is signed with a verified certificate, which is not the same as having it vetted by Microsoft's WHQL program. Thus, the driver signing requirement does not necessarily increase stability or security, which is all we end users really care about. Case in point: Silicon Labs' driver 6.0 is WHQL-certified and thus does not elicit any 'untrusted publisher' warnings when installed; however, this driver is known to suffer from serious stability issues (BSOD on surprise removal). On the other hand, we signed Silicon Labs' version 4.4 with a simple (verified) Authenticode code signing certificate, bypassing WHQL entirely (but of course forfeiting any hope of obtaining the coveted 'Certified for Windows' logo).
      What this all means is that 64-bit Windows will allow you to install a driver if and only if somebody vouches for it, nothing more and nothing less. If you have any questions or corrections, please contact us.